Tecalor heat pumps
Air/water monoblocGround sourceHot waterExhaust air 13 series
tecalor GmbH is a German heat pump and ventilation brand based in Holzminden and part of the Stiebel Eltron group; it sells through heating installers and wholesale, and its heat pumps are largely the same units Stiebel Eltron sells under its own name. The range covers the TTL comfort and eco R290 air-to-water monoblocks, the THZ integral units (heat pump plus ventilation), the TTF and TTC brine-to-water units and the TTA hot water heat pumps, controlled by the WPM heat pump manager with the ISG Connect TEC gateway.
Checked November 2, 2026 · Holzminden, Germany · Manufacturer website
Photo: Tecalor
Grant lists
BAFA WEP (Germany)
11 / 13 checked November 4, 2026
ZUM (Poland)
0 / 13 checked November 4, 2026
Tecalor in Zerofy
Zerofy has no integration for Tecalor yet. Where a series below has an SG Ready input, Zerofy can still switch it through a Shelly relay. The heat pump comparison lists every brand Zerofy supports.
Tecalor heat pump types
Tecalor Air-to-water monoblock
The whole refrigerant circuit sits in one outdoor unit; only water pipes run into the house. The most common choice for retrofits, because no refrigerant lines need to be installed inside.
Air/water monoblocR290
Tecalor TTL comfort
8 models
- Output
- 5–14.6 kW
- SCOP 35 °C
- 4.89–5.35
- Max. flow
- 75 °C
- BAFA WEP
- 8 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR290
Tecalor TTL eco
5 models
- Output
- 4.7–17.1 kW
- SCOP 35 °C
- 4.55–4.69
- Max. flow
- 75 °C
- BAFA WEP
- 5 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR452B / R454CDiscontinued
Tecalor TTL .6 (R454C / R452B)
4 models
- Output
- 4.4–12.6 kW
- SCOP 35 °C
- 4.31–4.35
- Max. flow
- –
- BAFA WEP
- 4 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR410ADiscontinued
Tecalor TTL (R410A)
15 models
- Output
- 4.1–13.5 kW
- SCOP 35 °C
- 4.11–4.87
- Max. flow
- –
- BAFA WEP
- 15 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Tecalor Ground-source (brine/water)
Draws heat from a borehole or ground loop, so the source stays at a steady temperature all winter. Higher efficiency and no outdoor noise, but boreholes cost money and need a permit.
Ground sourceR454C
Tecalor TTF .6
10 models
- Output
- 4.2–14.8 kW
- SCOP 35 °C
- 5.07–5.59
- Max. flow
- 75 °C
- BAFA WEP
- 10 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR454C
Tecalor TTC .6
10 models
- Output
- 4.2–14.8 kW
- SCOP 35 °C
- 5.07–5.59
- Max. flow
- 75 °C
- BAFA WEP
- 10 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR290
Tecalor TTF comfort (R290)
4 models
- Output
- 7–11.6 kW
- SCOP 35 °C
- 5.21–5.4
- Max. flow
- 70 °C
- BAFA WEP
- 4 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR290
Tecalor TTC comfort (R290)
4 models
- Output
- 7–11.6 kW
- SCOP 35 °C
- 5.21–5.4
- Max. flow
- 70 °C
- BAFA WEP
- 4 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR452BDiscontinued
Tecalor TTF / TTC .5 (R452B)
6 models
- Output
- 7.4–16.7 kW
- SCOP 35 °C
- 4.79–5.09
- Max. flow
- –
- BAFA WEP
- 6 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Tecalor Hot water heat pumps
A small heat pump built onto a hot water tank. It heats drinking water only and is a good way to turn surplus solar into stored heat – or to add hot water to a house that is otherwise heated differently.
Hot waterR290
Tecalor TTA comfort
3 models
- Output
- –
- SCOP 35 °C
- –
- Max. flow
- –
- BAFA WEP
- Not confirmed
- ZUM
- Not confirmed
- Zerofy
- Via SG Ready
Hot waterR290
Tecalor TTA topline
3 models
- Output
- –
- SCOP 35 °C
- –
- Max. flow
- –
- BAFA WEP
- Not confirmed
- ZUM
- Not confirmed
- Zerofy
- Via SG Ready
Tecalor Exhaust-air heat pumps
Take their heat from the ventilation air leaving the house. Compact and quiet, suited to well-insulated houses and small heating loads.
Exhaust airR290
Tecalor THZ .1 integral units
4 models
- Output
- 4.7–6 kW
- SCOP 35 °C
- 4.28
- Max. flow
- –
- BAFA WEP
- 4 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Exhaust airR410ADiscontinued
Tecalor THZ (R410A)
3 models
- Output
- 5.5–8.4 kW
- SCOP 35 °C
- 4.14–4.21
- Max. flow
- –
- BAFA WEP
- 3 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Tecalor series at a glance
| Series | Type | Output | SCOP 35 °C | SCOP 55 °C | Refrigerant | Max. flow | BAFA WEP | ZUM | SG Ready | Modbus | EEBUS |
|---|---|---|---|---|---|---|---|---|---|---|---|
| TTL comfort | Air/water monobloc | 5–14.6 kW* | 4.89–5.35 | 3.99–4.07 | R290 | 75 °C | 8 models listed | No model on the list | Yes | Yes | Yes |
| TTL eco | Air/water monobloc | 4.7–17.1 kW* | 4.55–4.69 | 3.79–3.85 | R290 | 75 °C | 5 models listed | No model on the list | Yes | Yes | Yes |
| TTL .6 (R454C / R452B) Discontinued | Air/water monobloc | 4.4–12.6 kW* | 4.31–4.35 | 3.45–3.9 | R452B / R454C | – | 4 models listed | No model on the list | Yes | Yes | Yes |
| TTL (R410A) Discontinued | Air/water monobloc | 4.1–13.5 kW* | 4.11–4.87 | 3.2–3.75 | R410A | – | 15 models listed | No model on the list | Yes | Yes | Yes |
| TTF .6 | Ground source | 4.2–14.8 kW | 5.07–5.59 | 4.02–4.42 | R454C | 75 °C | 10 models listed | No model on the list | Yes | Yes | Yes |
| TTC .6 | Ground source | 4.2–14.8 kW | 5.07–5.59 | 4.02–4.42 | R454C | 75 °C | 10 models listed | No model on the list | Yes | Yes | Yes |
| TTF comfort (R290) | Ground source | 7–11.6 kW | 5.21–5.4 | 4.05–4.19 | R290 | 70 °C | 4 models listed | No model on the list | Yes | ?Not confirmed | ?Not confirmed |
| TTC comfort (R290) | Ground source | 7–11.6 kW | 5.21–5.4 | 4.05–4.19 | R290 | 70 °C | 4 models listed | No model on the list | Yes | ?Not confirmed | ?Not confirmed |
| TTF / TTC .5 (R452B) Discontinued | Ground source | 7.4–16.7 kW* | 4.79–5.09 | 3.7–3.83 | R452B | – | 6 models listed | No model on the list | Yes | Yes | Yes |
| TTA comfort | Hot water | – | – | – | R290 | – | Not confirmed | Not confirmed | Yes | –Not documented | –Not documented |
| TTA topline | Hot water | – | – | – | R290 | – | Not confirmed | Not confirmed | Yes | –Not documented | –Not documented |
| THZ .1 integral units | Exhaust air | 4.7–6 kW* | 4.28 | 3.27–3.28 | R290 | – | 4 models listed | No model on the list | Yes | Yes | Yes |
| THZ (R410A) Discontinued | Exhaust air | 5.5–8.4 kW* | 4.14–4.21 | 3.28–3.3 | R410A | – | 3 models listed | No model on the list | Yes | Yes | Yes |
Heating output is the figure in the manufacturer's datasheet; the basis (nominal output at A7/W35 or B0/W35, or design heat load) differs between brands, so check the datasheet before comparing. * = design heat load Pdesignh at 35 °C from the BAFA portal.
Sources
Specifications come from the manufacturer's datasheets linked above, grant status from the official lists below, checked November 2, 2026:
- www.tecalor.de/de/produkte/waermepumpe/alle-produkte.html
- www.tecalor.de/de/produkte/lueftung/alle-produkte.html
- www.tecalor.de/de/produkte/regelung_energiemanagement/kommunikation/isg-connect-tec/isg...
- www.tecalor.de/content/dam/tec/de/de/downloads/202505_Kompatibilitaetsliste_ISG_TEC.pdf
- www.stiebel-eltron.de/toolbox/content/docs/anleitungen/installation/ISG_Modbus/321798-4...
- elan1.bafa.bund.de/zvi-ui/wep/waermepumpen
- BAFA Wärmeerzeuger-Portal – Wärmepumpen – checked November 4, 2026
- Lista ZUM (Instytut Ochrony Środowiska) – checked November 4, 2026
- EEBUS certified devices – checked November 2, 2026
SG Ready is a label of the Bundesverband Wärmepumpe (BWP) e.V.; “Yes” means the manufacturer documents the two-input interface or declares it on the BAFA portal, not that the series carries the BWP label – the label list is at waermepumpe.de. EEBUS is a standard of the EEBus Initiative e.V.; Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization. Product names, logos and photos belong to their manufacturers and are shown to identify the products. Grant data: BAFA Wärmeerzeuger-Portal and Lista ZUM (IOŚ-PIB) as of the dates shown; the SCOP at 55 °C in the BAFA tables is calculated by Zerofy from the portal's ηs value.
Heat with your own solar power
Zerofy moves your heat pump's runtime into the hours with surplus solar power or low prices – automatically.
Get ZerofyOther heat pump brands
Compare all brands in the heat pump database.