Novelan heat pumps
Air/water monoblocGround sourceHot waterExhaust air 17 series
NOVELAN is a heat pump brand of ait-deutschland GmbH in Kasendorf, Bavaria, the same company that makes alpha innotec heat pumps, and is sold through the three-tier wholesale channel to installers. Novelan traces its roots to the heat pumps Siemens built from 1976; the Kasendorf plant dates from 1998. The current range covers the Helox (R290), LADV and Jabbah air-to-water units, the GroundHub, SICV 6.3, WSV 6.3, SIC and SI brine-to-water units and the BW-S, WIB and ZLW hot water heat pumps, mostly controlled by the WPR-Net (Luxtronik) regulator.
Checked November 2, 2026 · Kasendorf, Germany · Manufacturer website · Datasheet library
Photo: Novelan
Grant lists
BAFA WEP (Germany)
13 / 17 checked November 4, 2026
ZUM (Poland)
3 / 17 checked November 4, 2026
Novelan in Zerofy
Zerofy has no integration for Novelan yet. Where a series below has an SG Ready input, Zerofy can still switch it through a Shelly relay. The heat pump comparison lists every brand Zerofy supports.
Novelan heat pump types
Novelan Air-to-water monoblock
The whole refrigerant circuit sits in one outdoor unit; only water pipes run into the house. The most common choice for retrofits, because no refrigerant lines need to be installed inside.
Air/water monoblocR290
Novelan Helox
5 models
- Output
- 4.9–17.2 kW
- SCOP 35 °C
- 4.95–5
- Max. flow
- 78 °C
- BAFA WEP
- 5 models listed
- ZUM
- 5 models listed
- Zerofy
- Via SG Ready
Air/water monoblocR290
Novelan Helox SE
4 models
- Output
- 4.1–10.6 kW
- SCOP 35 °C
- 4.75–5.15
- Max. flow
- –
- BAFA WEP
- 7 models listed
- ZUM
- 4 models listed
- Zerofy
- Via SG Ready
Air/water monoblocR290
Novelan LADV
4 models
- Output
- 7.6 kW
- SCOP 35 °C
- 4.9
- Max. flow
- 70 °C
- BAFA WEP
- 4 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR410A
Novelan Jabbah
2 models
- Output
- 4.9–5.6 kW
- SCOP 35 °C
- 4.54
- Max. flow
- 65 °C
- BAFA WEP
- 2 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR410A
Novelan LAV / LAVS
4 models
- Output
- 5.1–7.5 kW
- SCOP 35 °C
- 4.41–4.57
- Max. flow
- 60 °C
- BAFA WEP
- 16 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR410ADiscontinued
Novelan LIV / LICV
4 models
- Output
- 6.7–10 kW
- SCOP 35 °C
- 4.41–4.57
- Max. flow
- 60 °C
- BAFA WEP
- 10 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR454BDiscontinued
Novelan Polaris
3 models
- Output
- 5 kW
- SCOP 35 °C
- 4.58
- Max. flow
- 60 °C
- BAFA WEP
- 3 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR290Discontinued
Novelan LAD
8 models
- Output
- 6.8–10.1 kW
- SCOP 35 °C
- 4.02
- Max. flow
- 70 °C
- BAFA WEP
- 2 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Air/water monoblocR407CDiscontinued
Novelan LA
3 models
- Output
- 19.6–32.5 kW
- SCOP 35 °C
- 3.96
- Max. flow
- 60 °C
- BAFA WEP
- 1 model listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Novelan Ground-source (brine/water)
Draws heat from a borehole or ground loop, so the source stays at a steady temperature all winter. Higher efficiency and no outdoor noise, but boreholes cost money and need a permit.
Ground sourceR290
Novelan GroundHub
9 models
- Output
- 7.9–18.3 kW
- SCOP 35 °C
- 5.46–5.72
- Max. flow
- 70 °C
- BAFA WEP
- No model on the list
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR290
Novelan SICV 6.3 / WSV 6.3
4 models
- Output
- 6 kW
- SCOP 35 °C
- 5.14
- Max. flow
- 75 °C
- BAFA WEP
- 4 models listed
- ZUM
- 2 models listed
- Zerofy
- Via SG Ready
Ground sourceR410A
Novelan SIC
7 models
- Output
- 4.7–18.6 kW
- SCOP 35 °C
- –
- Max. flow
- 65 °C
- BAFA WEP
- 5 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR410A
Novelan SI
3 models
- Output
- 22.4–29.6 kW
- SCOP 35 °C
- –
- Max. flow
- 65 °C
- BAFA WEP
- 2 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Ground sourceR407CDiscontinued
Novelan SICV / WSV
7 models
- Output
- 5.4–15.9 kW
- SCOP 35 °C
- 5.18–5.26
- Max. flow
- 65 °C
- BAFA WEP
- 7 models listed
- ZUM
- No model on the list
- Zerofy
- Via SG Ready
Novelan Hot water heat pumps
A small heat pump built onto a hot water tank. It heats drinking water only and is a good way to turn surplus solar into stored heat – or to add hot water to a house that is otherwise heated differently.
Hot waterR134A
Novelan BW-S
2 models
- Output
- –
- SCOP 35 °C
- –
- Max. flow
- –
- BAFA WEP
- Not confirmed
- ZUM
- Not confirmed
- Zerofy
- Via SG Ready
Hot waterR134A
Novelan WIB
1 model
- Output
- –
- SCOP 35 °C
- –
- Max. flow
- –
- BAFA WEP
- Not confirmed
- ZUM
- Not confirmed
- Zerofy
- Via SG Ready
Novelan Exhaust-air heat pumps
Take their heat from the ventilation air leaving the house. Compact and quiet, suited to well-insulated houses and small heating loads.
Exhaust air
Novelan ZLW
2 models
- Output
- –
- SCOP 35 °C
- –
- Max. flow
- –
- BAFA WEP
- Not confirmed
- ZUM
- Not confirmed
- Zerofy
- Not supported
Novelan series at a glance
| Series | Type | Output | SCOP 35 °C | SCOP 55 °C | Refrigerant | Max. flow | BAFA WEP | ZUM | SG Ready | Modbus | EEBUS |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Helox | Air/water monobloc | 4.9–17.2 kW* | 4.95–5 | 3.63–3.9 | R290 | 78 °C | 5 models listed | 5 models listed | Yes | Yes | –Not documented |
| Helox SE | Air/water monobloc | 4.1–10.6 kW* | 4.75–5.15 | 3.38–3.98 | R290 | – | 7 models listed | 4 models listed | Yes | ?Not confirmed | ?Not confirmed |
| LADV | Air/water monobloc | 7.6 kW* | 4.9 | 3.75 | R290 | 70 °C | 4 models listed | No model on the list | Yes | –Not documented | –Not documented |
| Jabbah | Air/water monobloc | 4.9–5.6 kW* | 4.54 | 3.43 | R410A | 65 °C | 2 models listed | No model on the list | Yes | –Not documented | –Not documented |
| LAV / LAVS | Air/water monobloc | 5.1–7.5 kW* | 4.41–4.57 | 3.38–3.45 | R410A | 60 °C | 16 models listed | No model on the list | Yes | –Not documented | –Not documented |
| LIV / LICV Discontinued | Air/water monobloc | 6.7–10 kW* | 4.41–4.57 | 3.38–3.45 | R410A | 60 °C | 10 models listed | No model on the list | Yes | –Not documented | –Not documented |
| Polaris Discontinued | Air/water monobloc | 5 kW* | 4.58 | 3.53 | R454B | 60 °C | 3 models listed | No model on the list | Yes | –Not documented | –Not documented |
| LAD Discontinued | Air/water monobloc | 6.8–10.1 kW | 4.02 | 3.25 | R290 | 70 °C | 2 models listed | No model on the list | Yes | ?Not confirmed | ?Not confirmed |
| LA Discontinued | Air/water monobloc | 19.6–32.5 kW | 3.96 | 3.36 | R407C | 60 °C | 1 model listed | No model on the list | Yes | ?Not confirmed | ?Not confirmed |
| GroundHub | Ground source | 7.9–18.3 kW | 5.46–5.72 | 4.19–4.31 | R290 | 70 °C | No model on the list | No model on the list | Yes | –Not documented | –Not documented |
| SICV 6.3 / WSV 6.3 | Ground source | 6 kW | 5.14 | 3.95–3.96 | R290 | 75 °C | 4 models listed | 2 models listed | Yes | Yes | –Not documented |
| SIC | Ground source | 4.7–18.6 kW | – | 3.7–3.93 | R410A | 65 °C | 5 models listed | No model on the list | Yes | –Not documented | –Not documented |
| SI | Ground source | 22.4–29.6 kW | – | 3.7–3.78 | R410A | 65 °C | 2 models listed | No model on the list | Yes | –Not documented | –Not documented |
| SICV / WSV Discontinued | Ground source | 5.4–15.9 kW* | 5.18–5.26 | 3.9–4.13 | R407C | 65 °C | 7 models listed | No model on the list | Yes | –Not documented | –Not documented |
| BW-S | Hot water | – | – | – | R134A | – | Not confirmed | Not confirmed | Yes | –Not documented | –Not documented |
| WIB | Hot water | – | – | – | R134A | – | Not confirmed | Not confirmed | Yes | –Not documented | –Not documented |
| ZLW | Exhaust air | – | – | – | – | – | Not confirmed | Not confirmed | ?Not confirmed | ?Not confirmed | ?Not confirmed |
Heating output is the figure in the manufacturer's datasheet; the basis (nominal output at A7/W35 or B0/W35, or design heat load) differs between brands, so check the datasheet before comparing. * = design heat load Pdesignh at 35 °C from the BAFA portal.
Sources
Specifications come from the manufacturer's datasheets linked above, grant status from the official lists below, checked November 2, 2026:
- www.novelan.com/de/warmepumpen
- www.novelan.com/de/kontakt/uber-uns
- www.novelan.com/de/warmepumpen/zubehor/warmepumpenregelung-wpr-net
- www.novelan.com/de/warmepumpen/zubehor/warmepumpenregelung-hpm
- www.novelan.com/de/warmepumpen/grosswarmepumpen
- www.novelan.com/download/18.3bfdb88519994b0a9e437a4/1760599682354/Betriebsanleitung_WPR...
- www.novelan.com/de/warmepumpen/zubehor/myuplink
- dev.myuplink.com
- www.novelan.com/download/18.7138b2418661edafbc4d88/1678192481803/Bedienungsanleitung%20...
- www.novelan.com/download/18.7138b2418661edafbc4d8d/1678192521325/Bedienungsanleitung%20...
- elan1.bafa.bund.de/zvi-ui/wep/waermepumpen
- BAFA Wärmeerzeuger-Portal – Wärmepumpen – checked November 4, 2026
- Lista ZUM (Instytut Ochrony Środowiska) – checked November 4, 2026
- EEBUS certified devices – checked November 2, 2026
SG Ready is a label of the Bundesverband Wärmepumpe (BWP) e.V.; “Yes” means the manufacturer documents the two-input interface or declares it on the BAFA portal, not that the series carries the BWP label – the label list is at waermepumpe.de. EEBUS is a standard of the EEBus Initiative e.V.; Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization. Product names, logos and photos belong to their manufacturers and are shown to identify the products. Grant data: BAFA Wärmeerzeuger-Portal and Lista ZUM (IOŚ-PIB) as of the dates shown; the SCOP at 55 °C in the BAFA tables is calculated by Zerofy from the portal's ηs value.
Heat with your own solar power
Zerofy moves your heat pump's runtime into the hours with surplus solar power or low prices – automatically.
Get ZerofyOther heat pump brands
Compare all brands in the heat pump database.