Ground sourceR407CDiscontinued

Ochsner TERRA DX

Ground-source (brine/water) · 2 models

Ground source heat pump with direct expansion, where the refrigerant itself circulates through copper ground collectors instead of brine. Listed on the BAFA portal as direct-expansion/water units with R407C; not on Ochsner's current product pages.

Pdesignh12–16 kW
SCOP 35 °C5.49–5.59
SCOP 55 °C3.58–3.68
Max. flow–

Datasheet All Ochsner heat pumps

Grant lists

Grants depend on the exact model being on the official list. The counts below are the entries of this series we found in each list.

BAFA WEP (Germany)

2 models listed

2 models of this series are eligible in the BAFA Wärmeerzeuger-Portal, the list the German BEG heat pump grant depends on.

checked November 4, 2026 · See the entries

ZUM (Poland)

No model on the list

No model of this series is on the Lista ZUM, so it cannot be funded under Czyste Powietrze.

checked November 4, 2026

Specifications

TypeGround-source (brine/water)
Design heat load Pdesignh (35 °C)12–16 kW
SCOP at 35 °C5.49–5.59
SCOP at 55 °C3.58–3.68
RefrigerantR407C (GWP 1774)
Outdoor sound power–
Max. flow temperature–

Heating output is the figure in the manufacturer's datasheet; the basis (nominal output at A7/W35 or B0/W35, or design heat load) differs between brands, so check the datasheet before comparing. * = design heat load Pdesignh at 35 °C from the BAFA portal.

Control and connectivity

SG ReadyYes (declared by the manufacturer on the BAFA portal)
ModbusNot confirmed
EEBUSNot confirmed
Cloud APInot confirmed
§14a EnWG controlnot confirmed

Zerofy

Via SG Ready

Zerofy has no native Ochsner integration yet, but this series has an SG Ready input: Zerofy can switch it through a Shelly relay on the SG Ready terminals.

Ochsner in Zerofy

Models in this series

Model codes as the manufacturer documents them. The official list entries, with their own naming, follow below.

TERRA DX 11 HCUATERRA DX 15 HCUA

Models on the BAFA list 2

Eligible in the BAFA Wärmeerzeuger-Portal on November 4, 2026. Anlagennummer is the entry's number in the portal; SCOP at 55 °C is derived from the portal's ηs value.

ModelAnlagennummerSCOP 35 °CSCOP 55 °CSoundRefrigerantSG Ready
OCHSNER TERRA DX 11 HCUA 16000834 5.59 3.58 – R407C Yes
OCHSNER TERRA DX 15 HCUA 16000836 5.49 3.68 – R407C Yes

Entries as published in the official lists on the date shown; names and numbers are copied verbatim. Check the list for your exact model before you order.

Sources

  1. Datasheet: www.ochsner.com/fileadmin/downloads/OP/277030-TERRA%20DX%2011%20HCUA_DE.pdf
  2. BAFA Wärmeerzeuger-Portal – Wärmepumpen – checked November 4, 2026
  3. Lista ZUM (Instytut Ochrony Środowiska) – checked November 4, 2026
  4. EEBUS certified devices – checked November 2, 2026

All figures are taken from the manufacturers' datasheets and the official BAFA and ZUM lists on the date shown and may have changed since. This is not grant advice – check the list and your grant conditions before you order. Zerofy is not affiliated with any of the manufacturers listed.

SG Ready is a label of the Bundesverband Wärmepumpe (BWP) e.V.; “Yes” means the manufacturer documents the two-input interface or declares it on the BAFA portal, not that the series carries the BWP label – the label list is at waermepumpe.de. EEBUS is a standard of the EEBus Initiative e.V.; Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization. Product names, logos and photos belong to their manufacturers and are shown to identify the products. Grant data: BAFA Wärmeerzeuger-Portal and Lista ZUM (IOŚ-PIB) as of the dates shown; the SCOP at 55 °C in the BAFA tables is calculated by Zerofy from the portal's ηs value.

Heat with your own solar power

Zerofy moves your heat pump's runtime into the hours with surplus solar power or low prices – automatically.

Get Zerofy