Mitsubishi Electric Ecodan Eco Inverter split (SUZ-SWM)

Photo: Mitsubishi Electric

Air/water splitR32

Mitsubishi Electric Ecodan Eco Inverter split (SUZ-SWM)

Air-to-water split · 5 models

Single-phase split system for smaller heating loads (3 to 10 kW class), outdoor unit linked by refrigerant lines to a hydraulic module (ERSD) or cylinder module (ERST). The datasheet read (SUZ-SWM40VA2) gives a flow temperature up to 60 degrees C.

Pdesignh4–7.8 kW
SCOP 35 °C4.54–5.06
SCOP 55 °C3.33–3.48
Max. flow60 °C

Datasheet Product page All Mitsubishi Electric heat pumps

Grant lists

Grants depend on the exact model being on the official list. The counts below are the entries of this series we found in each list.

BAFA WEP (Germany)

85 models listed

85 models of this series are eligible in the BAFA Wärmeerzeuger-Portal, the list the German BEG heat pump grant depends on.

checked November 4, 2026 · See the entries

ZUM (Poland)

24 models listed

24 models of this series are on the Lista ZUM, which the Polish Czyste Powietrze grant requires.

checked November 4, 2026 · See the entries

Specifications

TypeAir-to-water split
Design heat load Pdesignh (35 °C)4–7.8 kW
SCOP at 35 °C4.54–5.06
SCOP at 55 °C3.33–3.48
RefrigerantR32 (GWP 675)
Outdoor sound power54–60 dB(A)
Max. flow temperature60 °C

Heating output is the figure in the manufacturer's datasheet; the basis (nominal output at A7/W35 or B0/W35, or design heat load) differs between brands, so check the datasheet before comparing. * = design heat load Pdesignh at 35 °C from the BAFA portal.

Control and connectivity

SG ReadyYes
ModbusYes (RTU, via Procon MelcoBEMS MINI (A1M / A1M+))
EEBUSNot documented
Cloud APInot confirmed (MELCloud)
§14a EnWG controlvia relay input
Local interfacesSG Ready, relay input, Modbus RTU (via Procon MelcoBEMS MINI (A1M / A1M+))

Source: www.mitsubishi-les.com/assets/documents/12288/12445/ph-ec... · library.mitsubishielectric.co.uk/pdf/download_full/2539 · library.mitsubishielectric.co.uk/pdf/download_full/5519

Zerofy

Via SG Ready

Zerofy has no native Mitsubishi Electric integration yet, but this series has an SG Ready input: Zerofy can switch it through a Shelly relay on the SG Ready terminals.

Mitsubishi Electric in Zerofy

Models in this series

Model codes as the manufacturer documents them. The official list entries, with their own naming, follow below.

SUZ-SWM30VASUZ-SWM40VA2SUZ-SWM60VA2SUZ-SWM80VA2SUZ-SWM100VA

Models on the BAFA list 85

Eligible in the BAFA Wärmeerzeuger-Portal on November 4, 2026. Anlagennummer is the entry's number in the portal; SCOP at 55 °C is derived from the portal's ηs value.

ModelAnlagennummerSCOP 35 °CSCOP 55 °CSoundRefrigerantSG Ready
SUZ-SWM100VA + EHSD-VM2E 16014264 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHSD-VM6E 16014265 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHSD-YM9E 16014266 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHST20D-VM2E 16014250 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHST20D-VM6E 16014251 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHST20D-YM9E 16014252 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHST30D-VM6EE 16014253 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + EHST30D-YM9EE 16014254 4.54 3.4 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERSD-VM2E 16014267 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERSD-VM6E 16014268 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERSD-YM9E 16014269 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST20D-VM2E 16014257 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST20D-VM6E 16014258 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST20D-YM9E 16014259 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST30D-VM2EE 16014260 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST30D-VM6EE 16014261 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM100VA + ERST30D-YM9EE 16014262 4.61 3.43 60.0 dB(A) R32 Yes
SUZ-SWM30VA + EHSD-VM2E 16014176 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHSD-VM6E 16014177 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHSD-YM9E 16014178 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHST20D-VM2E 16014373 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHST20D-VM6E 16014374 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHST20D-YM9E 16014164 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHST30D-VM6EE 16014165 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + EHST30D-YM9EE 16014166 4.84 3.33 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERSD-VM2E 16014179 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERSD-VM6E 16014180 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERSD-YM9E 16014181 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST20D-VM2E 16014169 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST20D-VM6E 16014170 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST20D-YM9E 16014171 4.99 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST30D-VM2EE 16014172 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST30D-VM6EE 16014173 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM30VA + ERST30D-YM9EE 16014174 4.95 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHSD-VM2E 16014198 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHSD-VM6E 16014199 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHSD-YM9E 16014200 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHST20D-VM2E 16014184 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHST20D-VM6E 16014185 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHST20D-YM9E 16014186 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHST30D-VM6EE 16014187 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + EHST30D-YM9EE 16014188 4.97 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERSD-VM2E 16014201 5.06 3.4 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERSD-VM6E 16014202 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERSD-YM9E 16014203 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST20D-VM2E 16014191 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST20D-VM6E 16014192 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST20D-YM9E 16014193 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST30D-VM2EE 16014194 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST30D-VM6EE 16014195 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM40VA2 + ERST30D-YM9EE 16014196 5.06 3.45 54.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHSD-VM2E 16014220 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHSD-VM6E 16014221 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHSD-YM9E 16014222 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHST20D-VM2E 16014206 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHST20D-VM6E 16014207 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHST20D-YM9E 16014208 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHST30D-VM6EE 16014209 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + EHST30D-YM9EE 16014210 4.7 3.43 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERSD-VM2E 16014223 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERSD-VM6E 16014224 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERSD-YM9E 16014225 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST20D-VM2E 16014213 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST20D-VM6E 16014214 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST20D-YM9E 16014215 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST30D-VM2EE 16014216 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST30D-VM6EE 16014217 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM60VA2 + ERST30D-YM9EE 16014218 4.8 3.48 56.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHSD-VM2E 16014242 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHSD-VM6E 16014243 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHSD-YM9E 16014244 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHST20D-VM2E 16014228 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHST20D-VM6E 16014229 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHST20D-YM9E 16014230 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHST30D-VM6EE 16014231 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + EHST30D-YM9EE 16014232 4.66 3.4 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERSD-VM2E 16014245 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERSD-VM6E 16014246 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERSD-YM9E 16014247 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST20D-VM2E 16014235 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST20D-VM6E 16014236 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST20D-YM9E 16014237 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST30D-VM2EE 16014238 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST30D-VM6EE 16014239 4.74 3.45 59.0 dB(A) R32 Yes
SUZ-SWM80VA2 + ERST30D-YM9EE 16014240 4.74 3.45 59.0 dB(A) R32 Yes

Models on the ZUM list 24

On the Lista ZUM on November 4, 2026, with the list's own device number.

ModelZUM id
SUZ-SWM100VA + ERSD-VM6EPW-417480
SUZ-SWM100VA + ERSD-YM9EPW-717488
SUZ-SWM100VA + ERST17D-VM6EPW-317490
SUZ-SWM100VA + ERST20D-VM6EPW-117491
SUZ-SWM100VA + ERST20D-YM9EPW-917492
SUZ-SWM100VA + ERST30D-VM6EEPW-717493
SUZ-SWM100VA + ERST30D-YM9EEPW-517494
SUZ-SWM40VA2 (-SC) + ERSD-VM6EPW-117453
SUZ-SWM40VA2 (-SC) + ERSD-YM9EPW-917454
SUZ-SWM40VA2 (-SC) + ERST17D-VM6EPW-617455
SUZ-SWM40VA2 (-SC) + ERST20D-VM6EPW-417456
SUZ-SWM40VA2 (-SC) + ERST20D-YM9EPW-217457
SUZ-SWM60VA2 (-SC) + ERSD-VM6EPW-017458
SUZ-SWM60VA2 (-SC) + ERSD-YM9EPW-017463
SUZ-SWM60VA2 (-SC) + ERST17D-VM6EPW-517465
SUZ-SWM60VA2 (-SC) + ERST20D-VM6EPW-317466
SUZ-SWM60VA2 (-SC) + ERST20D-YM9EPW-117467
SUZ-SWM80VA2 + ERSD-VM6EPW-017444
SUZ-SWM80VA2 + ERSD-YM9EPW-417442
SUZ-SWM80VA2 + ERST17D-VM6EPW-717445
SUZ-SWM80VA2 + ERST20D-VM6EPW-517446
SUZ-SWM80VA2 + ERST20D-YM9EPW-317447
SUZ-SWM80VA2 + ERST30D-VM6EEPW-717450
SUZ-SWM80VA2 + ERST30D-YM9EEPW-517451

Entries as published in the official lists on the date shown; names and numbers are copied verbatim. Check the list for your exact model before you order.

Sources

  1. Datasheet: www.mitsubishi-les.com/assets/documents/73728/76183/ps-ecodan-suz-swm40va2-er...
  2. Product page: www.mitsubishi-les.com/de-de/split-eco-inverter-hydromodul-heizen-kuehlen-298...
  3. Control and connectivity: www.mitsubishi-les.com/assets/documents/12288/12445/ph-ecodan-e-generation-de...
  4. Control and connectivity: library.mitsubishielectric.co.uk/pdf/download_full/2539
  5. Control and connectivity: library.mitsubishielectric.co.uk/pdf/download_full/5519
  6. BAFA Wärmeerzeuger-Portal – Wärmepumpen – checked November 4, 2026
  7. Lista ZUM (Instytut Ochrony Środowiska) – checked November 4, 2026
  8. EEBUS certified devices – checked November 2, 2026

All figures are taken from the manufacturers' datasheets and the official BAFA and ZUM lists on the date shown and may have changed since. This is not grant advice – check the list and your grant conditions before you order. Zerofy is not affiliated with any of the manufacturers listed.

SG Ready is a label of the Bundesverband Wärmepumpe (BWP) e.V.; “Yes” means the manufacturer documents the two-input interface or declares it on the BAFA portal, not that the series carries the BWP label – the label list is at waermepumpe.de. EEBUS is a standard of the EEBus Initiative e.V.; Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization. Product names, logos and photos belong to their manufacturers and are shown to identify the products. Grant data: BAFA Wärmeerzeuger-Portal and Lista ZUM (IOŚ-PIB) as of the dates shown; the SCOP at 55 °C in the BAFA tables is calculated by Zerofy from the portal's ηs value.

Heat with your own solar power

Zerofy moves your heat pump's runtime into the hours with surplus solar power or low prices – automatically.

Get Zerofy